VMIACC-5595-208
VMIACC-5595-208
解决您多处寻找的麻烦和对产品质量的担心等
在价格上我们有很大的优势,欢迎咨询,我们将会给您优致的服务!


GE热销:
GE697系列
诚信是用不完的资本,信誉是打不倒的招牌
如果您需要,我们能够解决您的缺损部分或交换。
IC697CPU772RR
IC697CPU780
IC697CPU780RR
IC697CPU781RR
IC697CPU782RR
IC697CPU788
IC697CPU788RR
IC697CPU789
IC697CPU789RR
IC697CPX772
IC697CPX772RR
IC697CPX782
IC697CPX782RR
IC697CPX928
IC697CPX928RR
IC697CPX935
IC697CPX935RR
IC697CSE784
IC697CSE784RR
IC697CSE924RR
IC697CSE925
IC697CSE925RR
IC697GDC701RR
IC697GDH701
IC697GDS701
IC697HSC700
IC697HSC700RR
IC697LBR701
IC697MDL240
IC697MDL240RR
IC697MDL241
IC697MDL241RR
IC697MDL250
IC697MDL250RR
IC697MDL251
IC697MDL251RR
IC697MDL252
IC697MDL252RR
IC697MDL253
IC697MDL253RR
IC697MDL254
IC697MDL254RR
IC697MDL340
IC697MDL340RR
IC697MDL341
IC697MDL341RR
IC697MDL350
IC697MDL350RR
IC697MDL640
IC697MDL640RR
IC697MDL650RR
IC697MDL651
IC697MDL651RR
IC697MDL652
At present, there are only four parameters of the product, namely module 485 address, communication baud rate, protocol selection and sampling rate. Therefore, this part mainly explains the setting and recovery process for these four parameters. The default 485 address of the product: 170, communication baud rate: 9600, protocol selection: the company's custom character protocol, sampling rate selection: low speed 10SPS. The following steps are illustrated by taking the 485 address, communication baud rate, protocol selection and sampling rate selection of the product as factory default parameters: 1) Connect the appropriate power according to parameter description and panel identification; 2) The 485 port of the product is connected with the RS232 port of the computer using the 485-232 module. If the computer does not have an RS232 interface, a USB to RS232 device is needed. 3) Use the conductor to shorten the SET and GND pins for 5 seconds and let the module enter the parameter modification state; 4) Open the attached serial debugging assistant software Commix, select ASCII mode, baud rate is 9600, data bit is 8, check bit N is none, stop bit 1. Enter the command: $AA2\CR, and then send it. If the return is correct, it means that the communication is correct. If there is no return, check whether the serial port selection, software Settings, USB to RS232, and 485 to 232 modules work normally, until the communication can be correct. 5) Set relevant parameters according to the NNTTCCFF\CR instruction. 6) Power on again, and the above parameters are the modified parameters. 7) After the successful modification, the parameters will not be lost if power is lost. The product can be directly connected to the corresponding network; Steps to restore factory parameters: 1) Disconnect the power supply; 2) Short connect SET and GND pins with the conductor, never relax or shake; 3) Power the product, disconnect the conductor of SET and GND pin after 5 seconds, and then the 485 address, communication baud rate, protocol selection and sampling rate selection of the product have been restored to the default factory parameters. 1. Connect all kinds of signal wires according to the interface description. 2. Select the DC power supply with voltage range of 10-30V and output current capacity of not less than 300mA to connect to the power port of the module; If the power indicator is on, it indicates that the power input is normal. Otherwise, the power should be unplugged immediately, and the power should be switched on after checking whether the power supply or module is normal. 3. Open the attached serial debugging assistant software Commix, and test each function according to the protocol selection and corresponding instructions. 1. Users can use configuration software to access operation modules. Of course, users can also write upper computer programs according to their specific applications. 2. Two protocols can be adopted to develop upper computer programs to operate the product. First, our custom character protocol is easy to remember and recognize, but the access efficiency is lower than the standard MODBUS_RTU protocol. The second is the standard MODBUS_RTU protocol. At the beginning, you need to have some understanding of MODBUS_RTU protocol, and you may need to test it back and forth for several times before you can successfully verify the calculation. However, with this protocol, the access efficiency is relatively high. 3. If the first method is used for programming, the field introduction of all instructions shall refer to "SK5000 series Product Square control Character Instruction System Description". 4. If the second method is adopted for programming, the register address, opcode and description of all instructions shall refer to SK5000 series product standard MODBUS_RTU Protocol Description. 1. The maximum external size: 120mm*71mm*43mm(including the thickness of the fixed seat for the back guide). 2. Installation method: standard industrial guide bar installation or screw hole installation.



客服1